National Electrical & Electronic Laboratory (West)      

Laboratory:

Our test reports are now recognized by most certification organizations. This helps the clients obtain product safety evaluation as well as certification. Our state-of-the-art well equipped laboratory and the qualified and courteous staff will take care of your product and help you attaining the levels as per the standards.

The Basic Facilities Provided


* Testing of Hardware Equipments and Systems
* Testing and validation of Software and Embedded Systems
* Help in improving the quality of the products to the standards

Test Facilities


* High voltage
* Earth Bond / Continuity
* Leakage Current
* Impact Hammer
* Stability
* Ball Pressure
* Cord Guard Flexing
* Input - Output Power Measurement
* Insulation Resistance
* Comparative Tracking
* Glow Wire
* Flammability
* Temperature Rise
* Creepage & Clearance
* Spring Operated Hammer
* Access to Live Parts
* Tensile Strength
* Elongation at Break
* Humidity
* Dimensional Observations
* Hot Deformation
* Ageing
* Irradiance/Radiation of UV and IR



  • According to IEC60601-1 (3rd Edition), Medical Electrical Equipment, Part 1-1: General Requirements for Safety - Collateral Standard, Safety Requirements for Medical Electrical Systems
  • According to IEC60601-1-2, Medical Electrical Equipment, Part 1-2: General Requirements for Safety - Collateral Standard : Electro Magnetic Compatibility
  • IEC60601-1-6; PART 1: GENERAL REQUIREMENTS FOR SAFETY - COLLATERAL STANDARD: USABILITY
  • IEC60601-1-8, PART 1-8: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE COLLATERAL STANDARD: GENERAL REQUIREMENTS, TESTS AND GUIDANCE FOR ALARM SYSTEMS IN MEDICAL ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS
  • IEC60601-2-37, MEDICAL ELECTRICAL EQUIPMENT PART 2-37: PARTICULAR REQUIREMENTS FOR THE SAFETY OF ULTRASONIC MEDICAL DIAGNOSTIC AND MONITORING EQUIPMENT
  • IEC60601-2-22, MEDICAL ELECTRICAL EQUIPMENT PART 2: PARTICULAR REQUIREMENTS FOR THE SAFETY OF DIAGNOSTIC AND THERAPEUTIC LASER EQUIPMENT
  • IEC60601-2-21, MEDICAL ELECTRICAL EQUIPMENT PART 2: PARTICULAR REQUIREMENTS FOR THE SAFETY OF INFANT RADIANT WARMERS
  • IEC60601-2-50, MEDICAL ELECTRICAL EQUIPMENT PART 2-50: PARTICULAR REQUIREMENTS FOR THE SAFETY OF INFANT PHOTOTHERAPY EQUIPMENT
  • IEC60601-2-2, MEDICAL ELECTRICAL EQUIPMENT PART 2-2: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF HIGH FREQUENCY SURGICAL EQUIPMENT AND HIGH FREQUENCY SURGICAL ACCESSORIES
  • IEC60601-2-24, PART 2: PARTICULAR REQUIREMENTS FOR THE SAFETY OF INFUSION PUMPS AND CONTROLLERS
  • IEC62304, MEDICAL DEVICE SOFTWARE SOFTWARE LIFE CYCLE PROCESSES
  • ISO9919, PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF PULSE OXIMETER EQUIPMENT FOR MEDICAL USE
  • IEC60204-1, SAFETY OF MACHINERY ELECTRICAL EQUIPMENT OF MACHINES PART 1: GENERAL REQUIREMENTS
  • And many more Product specific collateral standards

We undertake the testing of following types of products:

  CONSUMER PRODUCTS
  MEDICAL EQUIPMENTS
  PROCESS VALIDATION, TOXICOLOGY & BIOCOMPATIBILITY
  INDUSTRIAL PRODUCTS